GDP temperature monitoring requirements for wholesalers, in plain language
Short answer: the EU Good Distribution Practice guidelines expect a wholesaler to map each storage area before use, put monitors where the mapping found the extremes, calibrate them at defined intervals against a traceable standard, have alarms that reach a person in time and are tested, keep the records for at least five years in a system nobody can quietly change, and hold transport to the label's storage conditions. They do not prescribe a logger brand, a reading interval or a grace period: those come from your own risk assessment.
The text is the European Commission's Guidelines of 5 November 2013 on Good Distribution Practice of medicinal products for human use (2013/C 343/01), which applies to every holder of a wholesale distribution authorisation in the EU. National regulators inspect against it, sometimes with their own additions, and the Commission has published a short questions-and-answers document alongside it. The section numbers below are those of the guidelines; "Q&A" means the Commission's answers.
Before you store anything: mapping and placement
- Map the storage area before use (section 3.2.1). The guidelines ask for "an initial temperature mapping exercise … on the storage area before use, under representative conditions". The Commission's Q&A adds that it should be done in the seasons when the highest and lowest temperatures are reached, so one summer study is not the whole job.
- Repeat it when things change (3.2.1): according to a risk assessment, or whenever the building or the cooling equipment changes significantly.
- Put the monitors where the extremes are (3.2.1): "positioned in the areas that experience the extremes of fluctuations", as the mapping found them. How many probes is up to your risk analysis, not a fixed number (Q&A).
- A small room still needs thought. For premises of a few square metres at room temperature, the guidelines accept a risk assessment (a heater, a sunny wall) in place of a full mapping study.
The equipment: calibration and alarms
- Calibrate at defined intervals (3.3), "based on a risk and reliability assessment", and traceable "to a national or international measurement standard". Keep the records of calibration and maintenance for key equipment; the guidelines name cold stores as an example.
- Have alarms, set sensibly, and test them (3.3): "Appropriate alarm systems should be in place to provide alerts when there are excursions from pre-defined storage conditions. Alarm levels should be appropriately set and alarms should be regularly tested." The Q&A says the settings should "guarantee a timely alert of personnel". An alarm that sounds in an empty building at night, or lands in an inbox nobody reads until Monday, does not meet that.
- Qualify it before use (3.3.2), and again after significant changes such as a repair.
The records: what a computerised system has to do
Most monitoring is now software, so section 3.3.1 on computerised systems applies to it directly:
- Validate it before use. It must be shown, "through appropriate validation or verification studies", that the system gives the right results "accurately, consistently and reproducibly". The supplier can make this cheaper; the wholesaler still owns it.
- Describe it in writing: what it does, its security, and how it connects to other systems.
- Only authorised people enter or amend data, and data are "protected against accidental or unauthorised modifications".
- Back it up regularly, and keep backups "at least five years at a separate and secure location", checking from time to time that they can be read.
- Know what happens when it fails: a written procedure for a breakdown, including how data are restored.
Chapter 4 adds the general rule for documents: kept for the period national law sets, "but at least five years", and any change signed and dated in a way that leaves the original readable.
When something goes wrong
- Deviations are documented and followed by corrective and preventive actions (CAPA), a thread that runs through chapters 1 and 3.
- Returns need proof. A returned product that needs a specific storage temperature can go back to saleable stock only with "documented evidence that the product has been stored under the authorised storage conditions throughout the entire time" (chapter 6). If there was a deviation, a risk assessment has to show the product's integrity.
On the road: transport
- The label's conditions hold in transit (9.2): within "the defined limits as described by the manufacturers or on the outer packaging". The Commission's Q&A is blunt about shortcuts: a manufacturer agreeing to 2 to 25 °C for six hours does not let you leave the storage conditions; they apply at every stage of the transport chain.
- Transport monitoring equipment is calibrated at least once a year (9.2).
- Temperature-controlled vehicles are mapped under representative conditions, taking seasonal variation into account (chapter 9).
- An excursion in transport is reported to the distributor and the recipient, and there must be "a procedure … for investigating and handling temperature excursions" (9.2).
- Customers may ask for the evidence that products were kept within their temperature conditions in transit (chapter 9).
What the guidelines do not say
No reading interval, no number of minutes before an alarm, no particular technology, no requirement for a cloud system or against one. Those are decisions your written procedures make and justify from a risk assessment. An inspector will hold you to your own procedure, so write down the interval, the alarm delay and who is called, and make sure what you run matches it.
| Requirement | Where | The question an inspector asks |
|---|---|---|
| Initial mapping, repeated on change | 3.2.1 | Show me the mapping report and why the sensors are where they are. |
| Calibration, traceable | 3.3 | Is this logger's calibration in date, and against what standard? |
| Alarms that reach a person, tested | 3.3 | Who was alerted at 02:00, and when did you last test it? |
| Validated computerised system | 3.3.1 | Where is the validation, and who can change a reading? |
| Records kept at least five years | 3.3.1, chapter 4 | Show me the trace for this unit in March three years ago. |
| Transport within label conditions | 9.2 | How do you know this delivery stayed within range? |
| Excursions investigated and handled | 9.2, chapter 1 | What did you decide about this excursion, who decided, and why? |
Where ColdLatch fits, and where it does not
ColdLatch covers the monitoring and the record: readings from your loggers, alerts by email, Slack or Teams once an excursion is confirmed, each logger's calibration dates with a warning once one is overdue, a QA decision signed with a password and a reason, and an audit trail that shows if anyone changed it. Each excursion becomes a PDF report, and an inspection pack gathers a whole period into one file. What it does not do: the mapping study (you need sensors and a protocol for that), the calibration itself, or your validation. The security page says what we provide to make the validation cheaper, and what is not in place yet.
This article is general guidance, not regulatory advice. The quotations are from the guidelines as published in the Official Journal of the European Union (C 343, 23 November 2013) and the Commission's questions and answers on them; read the full text and your national regulator's requirements before you change a procedure.
Next: Mean kinetic temperature: when it helps and when it does not