ColdLatch

Guides

Mean kinetic temperature: when it helps and when it does not

Published 16 October 2026. 6 minute read.

Short answer: mean kinetic temperature (MKT) is the single steady temperature that would have done the product as much heat damage as the temperatures it actually saw. Warm hours count for more than in a plain average, so it is a fair way to weigh a fluctuating history against the manufacturer's stability data. It does not make an excursion acceptable on its own: it cannot see freezing, the number changes with the time window you choose, and the label's storage conditions still apply.

Where it comes from

Most chemical degradation speeds up as temperature rises, and not in a straight line: a few hours warm do more harm than the same hours an equal amount cold do good. MKT applies that curve (the Arrhenius equation) to a series of readings. For readings taken at equal intervals:

MKT = (ΔH/R) / −ln( (e−ΔH/RT₁ + e−ΔH/RT₂ + … + e−ΔH/RTₙ) / n )

with each temperature T in kelvin, R the gas constant, and ΔH the activation energy. By convention, as in the United States Pharmacopeia (general chapter <1079.2>, on MKT in the evaluation of excursions), ΔH is taken as 83.144 kJ/mol, which makes ΔH/R exactly 10,000 K. The real activation energy differs from product to product; the convention is a reasonable middle, not a property of your product.

Worked examples: a 2 to 8 °C cold room over 24 hours

Hourly readings, the room normally at 5 °C. Calculated with the same formula ColdLatch uses.

What happenedPlain averageMKT
24 hours at 5 °C5.0 °C5.0 °C
Half the day at 2 °C, half at 8 °C (never out of range)5.0 °C5.5 °C
23 hours at 5 °C, 1 hour at 15 °C5.4 °C5.8 °C
20 hours at 5 °C, 4 hours at 15 °C6.7 °C7.7 °C
20 hours at 5 °C, 4 hours at 25 °C8.3 °C12.9 °C

The gap between the two columns grows with the size of the spike. A plain average of 8.3 °C looks almost fine; an MKT of 12.9 °C says the product has had the equivalent of a full day well above its range.

When it helps

When it does not help, or misleads

A short procedure

  1. Look at the trace first: start, end, peak, and any gap in the readings.
  2. Low excursion? Leave MKT aside and judge on time below range and the product's freezing sensitivity.
  3. High excursion? Calculate MKT over the window your procedure names, and report the time out of range and the peak next to it, never the MKT alone.
  4. Compare with the stability data, or send all three figures to the manufacturer.
  5. Record the decision with the figures it was based on, who decided, and why.

How ColdLatch shows it

Each excursion in ColdLatch shows the minutes out of range and two MKT figures: over the excursion's own readings (the strictest window: it does not dilute the warm period with normal hours) and over the 24 hours from the start of the excursion, marked "so far" until those hours have passed. Both go into the PDF excursion report with the number of readings behind them, and a low excursion carries a note that MKT cannot show freezing. Where a profile sets a total time a batch may spend out of range, the alert also adds up every excursion the batch has been through.

This article is general guidance, not regulatory advice. Excursion limits and calculation windows come from the product's label, the manufacturer's stability data and your approved procedures; read the current USP and EU texts before relying on them.

Also: GDP temperature monitoring requirements for wholesalers, in plain language